Increasing filter loading
If the differential pressure increases at a comparable volume flow, the element becomes clogged with particles, oil or moisture and causes additional energy costs.
Products · Sensors · Filter differential pressure
A clogged filter wastes pressure and energy. Replacing it too early wastes materials and service time.
Why monitor?
The pressure drop across a filter indicates its actual flow resistance. Evaluated in relation to load, the measurement distinguishes normal pressure loss from fouling, overloading or a damaged filter element.
If the differential pressure increases at a comparable volume flow, the element becomes clogged with particles, oil or moisture and causes additional energy costs.
A high pressure loss even in the clean state indicates an excessively small filter, unfavorable pipe guidance or a permanently excessive volume flow.
An unexpectedly low pressure loss despite high loading can indicate an open bypass, an incorrectly inserted or damaged filter element.
In practice
Two pressure tapping points measure the differential pressure across the filter. An increase at comparable flow reveals additional compression demand.

Installation example: differential pressure measurement across a compressed air filter.
Original measurement report; source units and scales are retained in the image.
Open full-size imageIn practice
Example: 2-inch filter (DN 50), about 141,258,666.89 ft³ per year and a 75 kW compressor. Pressure loss rises from 1.45–5.08 psi. The manufacturer example gives about 0.3447 kW additional input per psi.

Calculation: 0.3447 kW/psi × 3.63 psi × 5,437 loaded hours × €0.16/kWh = €1,087.40 per year. At 6,000 loaded hours the result is €1,200. The filter element in the historical example costs €150. Original table with German labels.
Original measurement report; source units and scales are retained in the image.
Open full-size imageInteractive example
Adjust the example to your system. Results update as you type.
Extra energy cost per year
$1,087.400.3447 kW/psi × 3.63 psi × 5,437 h × $0.16/kWh = $1,087.40
Estimate assuming a constant additional pressure loss during loaded operation and a linear increase in compressor power per unit of pressure. Use the manufacturer’s data for your operating range. Element payback excludes labour and other service costs.
Example prices assume USD 0.16/kWh and USD 150 per filter element; these are editable illustration values, not converted quotations. Electrical power remains in kW. Use your own tariff and costs.
In the Airleader system
Current measured value and status are visible directly in the web visualization.
10-second averages make deviations, shifts and recurring patterns comparable.
limit violations are reported; Values are included in energy, quality or maintenance certificates.
Product documentation
This document describes the DP10 for monitoring filters, adsorption dryers and air treatment systems - from technical data to installation and electrical connection.

Initial technical consultation
In 30 minutes we clarify the station, load situation and the most sensible next step – free of charge and without preparation.