Paris, Illinois · United States

North American Lighting: coordinating two compressor rooms

A week of measurement identified excessive simultaneous compressor operation. Central control and simulation helped match the combination of machines to the plant’s actual demand.

Read the complete original report

Reported project result

27%less compressed-air energy
Before 100
After 73
Energy index · baseline = 100

01 · Starting point

The operating challenge

Five compressors from different manufacturers supplied two rooms. Data logging established a baseline; large variable-speed machines were running fully loaded instead of trimming demand.

02 · Implementation

What changed

The project connected the rooms through the existing Ethernet network and introduced coordinated control. Simulation used the measured demand profile to assess unloaded running.

03 · Results

The reported numbers

Reported energy reduction
27%
Annual electrical energy saved
Over 1,100,000 kWh
Reported annual cost savings
$91,000 USD
Reported payback
Less than one year

Historical project report referring to Compressed Air Best Practices, December 2018. Results and energy prices belong to that installation and period; they are not a savings guarantee for another site. The controller described is a historical model.